The Zinex Cobre salts come ready-mixed and should be added to city water in small increments,
while stirring continuously. No significant temperature will accrue during mixing. It is recommended
to filter the solution for several hours before use.

Procedure:
1. Leach tank with 10% volume/volume Sulfuric Acid.
2. Add water 80% of level.
3. Slowly stir in salts until fully dissolved.
a. Starter Salts Cobre @ 2.0 lb/gal, Strike @ 1.183 lb/gal
b. Liquid Additive @ 56 ml/gal

Solution Maintenance:
Routine analytical and trouble-shooting procedures are performed on a daily basis.

Temperature:
Although the Zinex Cobre bath can operate between 40ºF and 170ºF, the best results have been
obtained at 140º - 150ºF.

Copper Metal Mass:
7.2 grams (0.25 oz.)/square foot/0.0003 ins.